Goldline GL-235-LV Installation & Operation Manual

desired temperature, the valve will rotate allowing heat collection.

This heat collection will stop when the solar sensor falls to within

1.5 N F of the pool temperature or the pool temperature exeeds the

"desired temperature" set on dial.

AUTOMATIC COOLING: (Field selectable option) If the col-

lectors are cooler than the pool water by 6 N F or more, and the

pool is above the selected desired temperature, the valve will

rotate allowing cooling via the solar collectors. The heat dissipa-

tion will stop when the collectors rise within 3 N F of the pool tem-

perature or the pool temperature is lowered below the set desired

temperature.

SINGLE SETTING FOR DESIRED TEMPERATURE: The

GL-235 logic is set by a single dial adjustment with the desired

pool/spa temperatures clearly indicated. The dial is calibrated

with the temperatures from 70 N F to a high of 104 N F for quick and

easy, user-friendly operation. The temperature set indicates set

pool/spa temperature, and the GL-235 will automatically dete r-

mine if the water should be solar heated or cooled, thus maxi-

mizing the system capabilities.

Solar Pool Heating Control

# 1 1 B B e e s s t t S

# 1 1 B B e e s s t t S

Automatically Maximizes Solar System

Precise Calibrated Temperature Setting Dial

Single Model Handles all Systems-Old or New

Pools, Spas, 12 or 24VAC Actuators.

Automatic Switch Over from Solar Heating to

Nocturnal Cooling if Desired

Standard 120/240 VAC 50/60 Hz. Input

& 12 and 24 VAC Output

Goldline's Proven Reliability and Performance

Industry's Only 5-year Limited Warranty*

is GL-235 LV or GL-235 LV-HV

Control, Diverter Valve, Actuator & Sensors

S e e l l l l i i n n g g S

o l l a a r r C

S e e l l l l i i n n g g S

o l l a a r r C

TERMINAL STRIP CONNECTIONS: For input power, and

sensor inputs. Controls also have industry standard 3 pin connec-

tors for both forward and reverse valve actuator operation and

screw terminal connectors.

LED INDICATORS: Show the status of the system operation,

Four highly visible LED's show 1) power to the control, 2) power

output directing valves and/or pump to collect heat (heating), 3)

power output directing valves and/or pump to dissipate heat

(cooling), 4) sensor fault indicator shows sensor(s) not operating

GL-235 VALVE OUPUT: Rating is the industry standard 24

VAC. A jumper switches the output to 12VAC for compatibility

with older valve actuators. Output is fuse protected.

RECIRCULATION FREEZE PROTECTION: (field selectable

Operation) turns the GL-235 output ON, directing warmer

pool/spa water through the collectors when near freezing tempera-

tures are reached at the collector sensor. The GL-235 will allow

recirculation when the collector temperature rises to 42 N F. Two

10K Ohm sensors are required for operation. One or more freeze

snap switches are recommended if freeze recirculation protection

is utilized. Important--see installation instructions before using

Recirculation Freeze.

SYSTEM TEST SWITCH: Allows the user to manually over-

ride the automatic function of the GL-235 and verify operation.

Corporate Office:

42 Ladd Street

East Greenwich, RI 02818

(401) 884-6990

(401) 885-1500 Fax

Heat Collection

o n n t t r r o

o n n t t r r o

Western Regional Office:

7171 Alvarado Road, Suite 104

La Mesa, CA 91942

(619) 462-4298

(619) 462-4498 Fax

o l l l l e e r r

o l l l l e e r r

Table of Contents

Related Manuals for Goldline GL-235-LV

Temperature display for sp controls (4 pages)

Summary of Contents for Goldline GL-235-LV